    • 摘要: 采用显微组织观察、硬度测试等试验手段研究了不同温度和不同时间的时效处理对0Cr15Ni5Cu4Nb模具钢组织与硬度的影响。结果表明:经过1050℃×1 h固溶+不同温度时效保温6 h处理的0Cr15Ni5Cu4Nb钢组织主要为板条马氏体和颗粒状的富铜析出相。在320~460℃范围内,随着时效温度的升高,试验钢组织中的富铜析出相数量逐渐增加,尺寸逐渐增大。时效温度继续升高到520、580℃时,组织中马氏体发生分解。随着时效温度的升高、时效时间的增加,0Cr15Ni5Cu4Nb钢的硬度先升高后降低,经1050℃×1 h固溶+460℃×6 h时效处理的0Cr15Ni5Cu4Nb钢的硬度达到最大值43.5 HRC。

       

      Abstract: The effects of aging treatment at different temperatures and time on the microstructure and hardness of0Cr15Ni5Cu4Nb die steel were studied by means of microstructure observation and hardness test. The results show that the microstructure of 0Cr15Ni5Cu4Nb steel is mainly lath martensite and granular copper rich precipitates after solution treatment at 1050 ℃×1 h and aging treatment at different temperatures for 6 h. In the range of 320-460 ℃, with the increases of aging temperature, the number and size of copper rich precipitates increases gradually. When the aging temperature continues to increase to 520 ℃ and 580 ℃, the martensite in the microstructure decomposes. With the increase of aging temperature and aging time, the hardness of 0Cr15Ni5Cu4Nb steel first increases and then decreases. The hardness of 0Cr15Ni5Cu4Nb steel treated with 1050 ℃×1h solution+460 ℃×6h aging treatment reaches the maximum of 43.5 HRC.

       

    /