Vacuum Gas Nitriding Treatment of TC6 Titanium Alloy for Aeroengine
-
-
Abstract
TC6 titanium alloy for aviation was treated by vacuum gas nitriding to improve the surface wear resistance.The microstructure, hardness and wear resistance were analyzed by X-ray diffractometer, metallographic microscope, microhardness and wear tester.The results show that the phases of nitriding layer are mainly composed of TiN and Ti2N, and the nitrided layer of 50-70 μm is obtained after vacuum gas nitriding at 800 ℃for 8 h.The surface hardness can reach 800-830 HV, which is two times as much as that of untreated sample.The wear loss weight is only 1/12 of the untreated sample under the same conditions.The furrow is not clearly observed and the nitriding layer is basically intact.The wear resistance of nitrided TC6 titanium alloy are greatly improved.
-
-